Using the described simulation procedure, a simple commissioning service has been developed, which is either based on manufacturer data only or better on module IV curve measurements. The simulation models can be used from the system design and yield prediction over the commissioning process and subsequently during operational control and thus guarantee a very high quality assurance of PV generator operation. It could be shown that even with manufacturer data sheet information only, the simulation models can predict the measured yield with less than 5% error, if irradiance conditions are reasonably close to STC conditions, where the data sheet information is given.